Configurations General Guidelines and Requirements Restricted Locations Clearance Residential Barrier Make sure you have the following tools, before starting the installation: Crimping tool Torque wrench Drilling machine Level Phillips screwdriver Flat-blade screwdriver Cable cutter Wall plugs and screws Hammer WARNING! Install the battery according to national and local codes and standards and in locations compliant with local building codes and. Make sure to observe the following requirements, when selecting an installation site.
Do not install the Battery near heating equipment, ignition sources, or open flames. Install the Battery only on non-combustible surfaces and under non-combustible ceilings, overhangs, or eaves. Do not install the Battery within 3ft of gas meters, valves, regulators, lines, or gas appliances. Avoid installing the Battery in direct sunlight.
The battery must be secured to a wall using the supplied mounting bracket and the installation location must be adjacent to a wall. When installed indoors, the battery must not be obstructed by any building structure, room furniture or equipment. The battery shall not be exposed to direct sun or rain.
Connect the DC loads. Connect the PV. If applicable, connect the VE.Direct port. The correct connection order is necessary to allow the automatic system voltage detection to setup properly. It is only allowed to connect PV first when the system voltage is manually set before connecting the battery.
How many batteries can be installed in a tower?
Connect up to 5 battery modules in two towers (maximum 4 in a tower). The battery may be installed in an outdoor or indoor location. The battery must be secured to a wall using the supplied mounting bracket and the installation location must be adjacent to a wall.
Only qualified electricians shall install, troubleshoot, or replace the IQ Battery 3T or IQ Battery 10T. The IQ Battery system includes the Enphase IQ Batteries with integrated Enphase IQ Microinverters. The Enphase IQ Gateway measures PV production and home energy consumption.
IQ Batteries cannot be installed where L1 to L2 measures 208 VAC. ) Note that the rated energy capacity of the battery is 3.36 kWh. ) Install the PV system and the IQ Combiner as directed by the Enphase installation manuals. The IQ Battery housing is NEMA type 3R and can be installed indoors or out-doors.